Wednesday, December 7, 2011

Spa Plug Types


Spa Component Plug Types (Common)

There are many spa OEM's out there and each has their own preference for connector style. When purchasing retrofit components pay attention to the style!

Newer Hydro Quip & Gecko spa packs use JJ Style connectors each with a unique pin configuration & Color code for each piece of equipment. Th chart below is for Hydro Quip Systems.


We sell cord adapters/replacement for all of the above plug types. Purchasing adapters is the preferred option when a component requires a different plug style. We do not recommend splicing & joining wires.


Tuesday, December 6, 2011

Electronic Spa Control Error Codes


Electronic Spa Control Error Codes (by manufacture)


Manufacture Fault Description
Balboa
PD  Power Supply, Unit running on battery backup
OH  Over Heat ~ Sensors Reading 112-118 Degrees
FLO  Improper flow or pressure Switch Malfunction
Cool  Water Temp 20 Degrees below set point
ICE  Potential Frees Condition Detected
Sn1 Hi-Limit Sensor Malfunction
Sn3 Temperature Sensor Malfunction
ILOC  Interlock Failure ~ Possible Pump or Ozone Spike


Brett Digital
OH Temp Exceeds 118 Degrees 
Fr   Freeze condition - temp below 40
FL  Pressure switch failure
EO  Shorted temp sensor
E1  Open temp sensor
E2  Shorted hi-limit sensor
E3  Open Hi-limit sensor
E4  Shorted flow switch
E7  Improper Electrical Connection
FC  Filter Cycle 


Hurricane
PS   Improper flow or pressure Switch Malfunction
SH   Shorted Sensor
OP   Open Sensor
LO   Temperature Below 60 Degrees ~ Freeze
HI   High Temperature warning, Above 118 Degrees


Sundance
ILOC  Interlock Failure ~ Possible Pump or Ozone Spike 
OH Sensor indicates water Temperature above acceptable limits 
FLO Pressure Switch Malfunction 
Hold   Panel buttons pressed too many times too quickly
HOT   Circuit Board Temperature Above Acceptable limits
ICE   Freeze condition Detected
PnL  Communication Failure between PCB and Panel
Sn1 Hi-limit sensor Failure
Sn3  Temperature Sensor Failure
-- Watch dog ~ Potential damage to Spa Equipment


Gecko
FLO Pressure Switch Failure ~ Switch Open
FLC Pressure Switch Failure ~ Switch Closed
Prr  Temperature Sensor Failure
Prh Hi-limit sensor Failure
HL Over Heat ~ Water Temp at 119 Degrees
FrE Possible Freeze condition


Lennovator
FP Freeze Point 
SP  SPA MODE< not an error
PO  POOL MODE< not an error
NC  No Communication with Master Control Unit
--  Data being sent to MCU
OP  Temp Sensor Failure - Open
SH  Temperature Sensor Failure - Shorted
OH WARNING - Water Temp over 120 Degrees 
IP Insufficient Power
"Temperature" Set Point & Actual Water Temp
"Temperature" Flashing WARNING - Water Temp High (109-120F)


Spa Builders LX 10/15 
Sn1 / 01 Nonfunctional/open high temp sensor - Heater deactivated 
Sn2 / 02 Nonfunctional/open temp sensor - Heater deactivated .
FL1 / 03 Pressure switch not closing when pump is running and heater is trying to heat. Heater is also deactivated. 
FL2 / 04 Pressure switch closed when pump is off.              
COL / 05 Cool Water Condition, Temp falls 20 degrees below set temp.
ICE  Freeze condition, pump and heater activate at 55 degrees.
OH Water Temp Above 110 degrees.
---  Watchdog water temp above normal limits (above 118) potential system failure.  


Balboa M7
OHH or OH Water Temp Over Heat
OHH or HH Heater Housing Over Heat
SnS or Sn Sensor Balance error
SnA or SA Sensor A failure
SnB or Sb Sensor B failure
dr Possible dry fire detected
dy Dry heater detected
HL Possible low heater flow
LF Low flow thru heater
Message Codes
Pr Priming Mode 4 Min
St Standard Operation
Ec Economy Mode
SL Sleep
IC Freeze Condition Detected
- Water Temp Unavailable


























Wednesday, September 21, 2011

Winterizing your Spa or extended period shutdown



If you don’t have plans to use your spa during the winter months, you should drain it completely well before the temperatures get low enough to produce a hard freeze.

Hot tubs that are heavily used by bathers should be drained every 3 – 4 months. When it’s time to drain, either drain to a sanitary sewer or use the water for lawn irrigation. Make sure no chemicals have been added for at least 48 hours before draining.

Water in spas filled with sprayed foam insulation will still freeze if not heated. Finding and fixing leaks in that foam is a nightmare! These recommendations could potentially save you a lot of money!
    
These basic steps will ensure safe, effective shutdown of your spa for the winter months or any other extended period with out use. Factors such as spa installation, location, type will affect the steps and procedures.
Use these  recommendations as a guide.
  • Disconnect the spa from the power supply.
  • Open the drain valve (if installed) or pump out all water.
  • Remove the filter cartridge(s). Clean & store in a dry place. (FILTER FLOSSER)
  • If possible attach a wet/dry (shop) vacuum (capable of blowing air as well as vacuuming) to the hole in the bottom of the filter housing.
  • Using the blower function, blow out any excess water through the plumbing system - allow a good 5 minutes of blowing time.
  • Use the shop vac to remove any water blown through the jets into the tub or towel dry any remaining water from the spa, until it is completely dry.
  • Leave drain & gate valves open, if you have rodent issues we recommend MOUSE AWAY.
  • Close the spa cover and fasten with tie down safety locks.

This is not a job you want to do in freezing conditions, give yourself enough time. Make every effort to ensure ALL of the water is removed – including remnants in the pump lines and jets.
These are common sense steps always be safe around water and electricity.

What jets does my spa have?


Trying to find out which brand of jets your spa has can be tricky.
We have a basic list of the spa brands we come across most often & the jet manufacture they use. This is by no means a complete list but a good starting point. We never assume anything, always double check if you are not sure - there are always exceptions!


CalSpa*, Centurion Spas, Dimension One
Spas, Down East Spas, Emerald, Great Lakes Spas, Life Spa, Marquis, Master Spas(Some Models), Reflections Spas, Thermospa, Viking & Vita Spas.


Artesian Spas, Barefoot Spas, Coleman Spas, Cool Nights Spas, Coast Spas, Clear Water Spas, Charisma Spas, Catalina Spas, Blue Ridge Spas, Beachcomber Spas, Day Break Spas, Diamante Spas, Dolphin Spas, Dynasty Spas, Four Wind Spas, Garden Leisure Spas, Gulf Coast Spas, Hawk Eye Spas, Keys Spas, LA Spas, Leisure Bay Spas, Master Spas (newer Models), Maxx Spas, Phoenix Spas, Savannah Spas, Sunrise Spas, Weslo - Icon -  Image - Proform Spas.


The spa industry is very complex often one manufacturer will make multiple "name brands" of spas. One good example is Maax Spas (which use both Pentair & Waterway) they make or have made spas under the following names at one point or another: California Cooperage, Coleman Spas, Elite Spas, Infiniti Spas, Journey, Lifestyle Spas, MAAX, Nahanni Spas, Power Pool, Savannah Spas, Vita Spa.

*Cal-Spas use Pentair jets with proprietary jet face sizes & designs, we often sell regular Pentair jets as lower priced substitutes.